More Informations

Zoom Image

Download Data Sheet

Wiring Diagram

Dimensions
|
BF93: Wind Speed Control.
BF93 was created to control wind speed.
The reading can be assigned to one or two external probes: however, using a sole probe it is possible to use two alarm thresholds. The speeds detected are shown on the display and the maximum values are saved.
The control unit is equipped with two outputs with independent settings: alarm speed, output activation delay time, and output deactivation delay time. Two LEDs on the front panel indicate the status of the two outputs.
The unit of measure can be set in km/h, m/s or knots.
The programming can be protected against modifications by closing clamps 17 and 18 on the control unit.
More Informations
Application sectors
Greenhouses automation, curtains automation, domotics.
Technical Characteristics
Download Data Sheet
Supply Voltage |
230 V - 50 Hz |
Consumption |
5 VA |
Type of output |
2 relays, exchange contact, max 3A |
Control unit function range |
0-45 °C with 0-90% humidity |
Display of alarms |
Two LEDs on the front panel |
Display |
LCD display 2x16 backlight |
Unit of measure |
Km/h, m/s, Knots |
Alarm delays |
0-9999 seconds |
Probe Range |
0,0 - 99,9 Km/h (m/s, knots) |
Type of connections |
2.5 mm2 screw clamps |
Type of installation |
Front panel, hole 92x92 mm |
Control Unit protection level |
IP40 |
External probe protection level |
IP55 |
Connection of external probe |
2 wires (max. recommended distance 50 m) |
|